logo
Envoyer le message
Maison
Produits
Vidéos
Au sujet de nous
Visite d'usine
Contrôle de qualité
Contactez-nous
Demande de soumission
Nouvelles
Nouvelles de société
BOGEN PUMPS
Aperçu ProduitsPompe de transfert de diaphragme

Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

La Chine BOGEN PUMPS certifications
La Chine BOGEN PUMPS certifications
BA50 EST BON POUR L'INSTANT

—— Puits de travail

Le bon travail, merci de me donner de grandes vacances. Meilleurs voeux, Vinod

—— Vinod Bernardo

Coopération gentille ! Nous avons apprécié pour l'appui aimable de votre société sur nos projets. Service très bon

—— M. Hussain

Je suis en ligne une discussion en ligne

Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration
 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

Image Grand :  Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

Détails sur le produit:
Lieu d'origine: La Chine
Nom de marque: BSK
Numéro de modèle: BSKA25AL-P99-A
Conditions de paiement et expédition:
Quantité de commande min: 10 unités
Prix: negotiable
Détails d'emballage: Bois
Délai de livraison: 5 JOURS
Conditions de paiement: GOUSSET T/T
Capacité d'approvisionnement: 1000 unités par mois
Garantie :: Un an
Description de produit détaillée
Nom du produit: pompe à diaphragme pneumatique Matériau: Acier moulé
Pression atmosphérique maximale: 8.3bar le bruit: <80db>
Max. Installation Dimension: 249.5×360.5×245mm Écoulement maximal: 135L/MIN
Mettre en évidence:

food grade diaphragm pump

,

air operated submersible pump

Positive Displacement Water Pump Air Operated With Low Vibration

 

 

Air diaphragm pump(also know as a Membrane pump, air operated double diaphragm pump(AOOD) or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.

 

Product Description:

 

Air Inlet

1/4-18NPTF-1

Fluid Outlet

1-11-1/2NPTF-1,Rp1-11BSP

Fluid Inlet

1-11-1/2NPTF-1,Rp1-11BSP

Max. Flow

135L/Min

Max. Head

70M

Max. Self-priming Lift (dry)

4m

Max. Air Pressure

8.3bar

Max. Particle Diameter

3mm

Max. Installation Dimension

249.5×360.5×245mm

Weight

9.5kg

Noise

<80db

 

 

Specifications

 

Air Diaphragm Pump
1. Non leakage
2. Good self priming performance
3. Convey all kinds of medium
4. Material:Cast steel,Alu,SS,PP

 

Pneumatic Diaphragm Pump Advantages:

1. Explosion-proof, zero leak, simple operation.

2. Idling capability,Self suction, No complex control.

3. Diversity of material,no rotating parts,applicable to various erosive situations.

4. Diaphragm, ball and ball seat adopt imported materials with longer service life.

5. Modularization of main valve and air motor. No broken, easy to disassemble and repair.

 

Pay attention to the following points when operating with a pneumatic diaphragm pump:


1. Ensure that the maximum particles contained in the fluid do not exceed the maximum safety of the pump through the particle diameter standard.
2. The intake pressure should not exceed the maximum allowable pressure of the pump. Compressed air above the rated pressure may cause personal injury and property damage and damage the performance of the pump.
3. Ensure that the pumping piping system can withstand the highest output pressure achieved, and ensure the clean and normal working conditions of the driving pneumatic system.
4. Static sparks may cause explosions and personal injury and property damage. Use wires with a large cross-sectional area as needed to properly ground the grounding screws on the pump.
5. The grounding requirements are in compliance with local laws and regulations and some special requirements on site.
6. Tighten the pump and each connecting pipe joint to prevent static sparks from being generated by vibration. Use an antistatic hose.
7. Periodically check and test the reliability of the grounding system, requiring a grounding resistance of less than 100 ohms.
8. Maintain good exhaust and ventilation, away from inflammable, explosive and heat sources.

Maximum Applied Temperature Limits (diaphragm / ball / seal material)  

 

 

Acetal ···············································40°-         150°F        (4.4- 65.5°C)  

Santoprene····················································-40°- 225°F (-40°- 107.2°C)   ·····································································40°- 220°F (4.4°- 104°C)   Nitrile·······································································10°- 180°F (-12°- 82°C)   Viton······························································-40°- 350°F (-40°-176.6°C)   Hytrel·········································································-20°-150°F (-12°- 93°C)   Kynar·····································································10°-200°F (-28.9°- 65.5°C)   Polypropylene····················································32°- 175°F (0-79.4°C)

 

 

1”  Flow diagram

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 0

 

Installation dimensions:

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 1

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 2

 

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 3

 

 

 

 


 

 

Coordonnées
BOGEN PUMPS

Personne à contacter: Mr. ALLSON

Téléphone: 008618122100289

Envoyez votre demande directement à nous (0 / 3000)